Centreon Web
CVE-2025-8430
MEDIUM
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessObtain elevated Centreon account
-
DeliveryInject script into Commands Connectors config
-
ExploitPayload stored in configuration module
-
ExecutionVictim user opens affected page
-
ImpactScript executes in victim browser session
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Output encoding, context-aware escaping
MITRE ATT&CK
2 techniques across 2 tactics: Initial Access, Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Requires an authenticated user with elevated/administrative privileges (PR:H) who can write to the Commands Connectors configuration modules of Centreon Infra Monitoring (Centreon Web) to store the malicious payload. Exploitation is further gated by required user interaction (UI:R): a second user must subsequently load the affected configuration page for the stored script to execute. Limiting factors that reduce real-world risk: the high-privilege barrier to plant the payload, the need for victim interaction, and that only specific affected version ranges (24.10.0-24.10.12, 24.04.0-24.04.17, 23.10.0-23.10.27) are vulnerable. No availability impact. |
| Impact | This is a genuinely low-priority, medium-severity issue rather than an urgent one, and the signals are consistent. The CVSS 3.1 vector (AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N, base 4.8) describes a stored XSS that requires a high-privilege authenticated account to plant the payload and a second user's interaction to trigger it, with only low confidentiality and integrity impact and no availability impact. EPSS reinforces this: 0.21% probability at the 10th percentile indicates very low expected real-world exploitation. The vulnerability is NOT on the CISA KEV list (no confirmed active exploitation) and there is no public exploit identified at time of analysis, so this is theoretical risk only. No signals conflict - the high-privilege prerequisite (PR:H), required user interaction (UI:R), and low EPSS all point the same direction. The main caveat is that the elevated-privilege requirement means the attacker is already a trusted administrator, so realistic impact is largely limited to privilege-escalation-adjacent or insider/compromised-admin scenarios; the scope change (S:C) reflects that injected script executes in other users' browser sessions. |
| Exploit ScenarioDerived | An attacker who already holds an elevated/administrative Centreon Web account injects a malicious script into the Commands Connectors configuration fields. When another authenticated user later views that configuration page, the stored payload executes in their browser session (UI:R), potentially stealing session data or performing actions as that user. No public exploit code is known, and the high-privilege prerequisite makes this most relevant to compromised-admin or insider scenarios. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 08, 2026
Stored cross-site scripting (XSS) in the Commands Connectors configuration modules of Centreon Web (Centreon Infra Monitoring) allows an authenticated user with elevated or administrative privileges to persist malicious script content that executes when another user later loads the affected configuration page. The issue affects three branches: 23.10.0 through 23.10.27, 24.04.0 through 24.04.17, and 24.10.0 through 24.10.12. No public exploit code has been identified at time of analysis and the vulnerability is not listed in CISA KEV; EPSS is 0.21% (10th percentile), reflecting a low-priority, medium-severity issue rather than an urgent one, since exploitation is gated by a high-privilege account plus victim interaction.
RemediationAI
Vendor-released patch: upgrade to Centreon Web 24.10.13, 24.04.18, or 23.10.28 depending on your release train, as documented in the vendor bulletin at https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-8430-centreon-web-all-versions-medium-severity-5118 and the release notes at https://github.com/centreon/centreon/releases. Because exploitation requires an authenticated high-privilege account plus a victim opening the affected configuration page, interim compensating controls should focus on privilege minimization and session hardening: audit and reduce the set of accounts with rights to edit Commands Connectors configuration, and apply strict least-privilege role assignments so that only trusted administrators can write to those modules (trade-off: may slow legitimate configuration workflows and requires ongoing review). Enforce a restrictive Content-Security-Policy on the Centreon web interface to reduce script execution impact, and consider network-level restrictions or a reverse proxy limiting the administration UI to trusted networks or VPN (trade-off: reduces convenience for remote administrators). Educate administrative users not to open unsolicited or untrusted configuration links, since the attack chain depends on user interaction. No vendor-supplied workaround was identified beyond upgrading to the patched versions.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The root cause is CWE-79, improper neutralization of user-supplied input during web page generation, in the Commands Connectors configuration modules of Centreon Web - a PHP/MySQL-based IT infrastructure monitoring platform. Because the payload is stored server-side and rendered back to other users on the configuration page, this is a persistent (stored) rather than reflected XSS. The CVSS 3.1 vector CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N confirms network reachability, high privileges required to plant the payload, mandatory user interaction for the payload to fire, and a changed scope that limits confidentiality and integrity impact to low with no availability impact. CPE data identifies the affected component as centreon:centreon_web, with three affected version ranges corresponding to the 23.10, 24.04, and 24.10 release trains. Attackers must already hold an elevated role capable of writing to the Commands Connectors configuration; the XSS then executes in the session context of a subsequent viewer of that configuration.
Know when Centreon Web gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Stored XSS requires a high-privilege account to inject (PR:H) and a victim to render the page (UI:R); script runs in another user's context (S:C) with limited C/I impact and no availability loss.
Primary rating from NVD.
CVSS VectorNVD
DescriptionNVD
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Centreon Infra Monitoring (Commands Connectors configuration modules) allows Stored
XSS by users with elevated privileges.
This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Cross-Site Scripting occurs when an application accepts untrusted data and sends it to a web browser without proper validation or encoding.
Affected Products (CPE)NVD
More in Centreon Web
View allAuthenticated OS command injection in Centreon Web (Infra Monitoring) lets a high-privilege user execute arbitrary opera
minPlayCommand.php in Centreon Web before 2.8.27 allows authenticated attackers to execute arbitrary code via the comman
Centreon Web 19.04.4 has weak permissions within the OVA (aka VMware virtual machine) and OVF (aka VirtualBox virtual ma
Centreon Web before 2.8.30, 18.10.x before 18.10.8, 19.04.x before 19.04.5 and 19.10.x before 19.10.2 allows Remote Code
Local file inclusion in brokerPerformance.php in Centreon Web before 2.8.28 allows attackers to disclose information or
A SQL Injection vulnerability exists in the updateServiceHost functionality in Centreon Web 24.04.x before 24.04.3, 23.1
Multiple SQL injection vulnerabilities in Centreon 3.4.6 including Centreon Web 2.8.23 allow attacks via the searchU par
There is Remote Code Execution in Centreon 3.4.6 including Centreon Web 2.8.23 via the RPN value in the Virtual Metric f
A SQL Injection vulnerability exists in the Graph Template component in Centreon Web 24.04.x before 24.04.3, 23.10.x bef
A SQL Injection vulnerability exists in the Timeperiod component in Centreon Web 24.04.x before 24.04.3, 23.10.x before
A SQL Injection vulnerability exists in the Downtime component in Centreon Web 24.04.x before 24.04.3, 23.10.x before 23
A SQL Injection vulnerability exists in the service configuration functionality in Centreon Web 24.04.x before 24.04.3,
NVD
CVE.org
EPSS
GitHub
Exploit-DB