Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/U:Red
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/U:Red
Lifecycle Timeline
3DescriptionCVE.org
An OEM IP camera manufactured by Shenzhen Liandian Communication Technology LTD exposes a Telnet service (port 23) with undocumented, default credentials. The Telnet service is enabled by default and is not disclosed or configurable via the device’s web interface or user manual. An attacker with network access can authenticate using default credentials and gain root-level shell access to the device. The affected firmware version is AppFHE1_V1.0.6.0 (Kernel: KerFHE1_PTZ_WIFI_V3.1.1, Hardware: HwFHE1_WF6_PTZ_WIFI_20201218). No official fix or firmware update is available, and the vendor could not be contacted. This vulnerability allows for remote code execution and privilege escalation.
AnalysisAI
CVE-2025-7503 is a security vulnerability (CVSS 10.0). Critical severity with potential for significant impact on affected systems.
Technical ContextAI
CWE-798 (Hard-coded Credentials). CVSS 10.0 indicates critical severity with likely remote exploitation vector.
RemediationAI
Monitor vendor channels for patch availability.
A command injection vulnerability (CVSS 9.8). Risk factors: public PoC available.
Plaintext daemon credentials in IDC SFX2100 routing config files (zebra, bgpd, ospfd, ripd). CVSS 10.0. PoC available.
Kede Electronics IoT smart water meter monitoring platform v1.0 has a SQL injection allowing attackers to compromise the
RIOT IoT operating system has an out-of-bounds read vulnerability (CVSS 9.1) that could lead to information disclosure o
A buffer overflow vulnerability in A vulnerability classified as critical (CVSS 8.8). Risk factors: public PoC available
CVE-2025-34023 is a path traversal vulnerability in Karel IP1211 IP Phone's web management panel that allows remote auth
CVE-2025-48466 is a security vulnerability (CVSS 8.1). Risk factors: public PoC available.
MajorDoMo's unauthenticated /objects/?op=set endpoint fails to sanitize property values, allowing remote attackers to in
Command injection via the hostname field allowing authenticated code execution with maximum CVSS 10.0 and scope change.
Synectix LAN 232 TRIO serial-to-ethernet adapter exposes its web management interface without authentication (CVSS 10.0)
An API authentication bypass allows unauthenticated attackers to impersonate legitimate users. Maximum CVSS 10.0 with sc
CVE-2025-48890 is a critical OS command injection vulnerability in the miniigd SOAP service affecting WRH-733GBK and WRH
Same weakness CWE-798 – Use of Hard-coded Credentials
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2025-21182