Severity by source
CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Adjacent network, low privileges required, low availability impact.
Primary rating from NVD.
CVSS VectorNVD
CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Lifecycle Timeline
6DescriptionCVE.org
A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been classified as problematic. This affects an unknown part of the file /boafrm/formFilter of the component HTTP POST Message Handler. The manipulation of the argument url leads to denial of service. The exploit has been disclosed to the public and may be used.
AnalysisAI
Denial of service in TOTOLINK N300RH firmware 6.1c.1390_B20191101 via the /boafrm/formFilter endpoint allows an authenticated attacker on the local network to crash the device by manipulating the 'url' argument. A public exploit is available, but no active exploitation has been reported (not in CISA KEV). EPSS score is low (0.14%), indicating low exploitation likelihood.
Technical ContextAI
The vulnerability resides in the HTTP POST message handler of the TOTOLINK N300RH router, specifically in the /boafrm/formFilter file. The CWE-404 (Improper Resource Shutdown or Release) indicates that the software does not properly release resources after handling a request, leading to a denial of service. The affected product is a consumer-grade router running firmware version 6.1c.1390_B20191101, as identified by the CPE string cpe:2.3:o:totolink:n300rh_firmware:6.1c.1390_b20191101:*:*:*:*:*:*:*.
RemediationAI
No vendor-released patch has been identified at the time of analysis. As a workaround, restrict access to the router's management interface to trusted devices only, e.g., by disabling remote management or using firewall rules to block unauthorized IPs. Note that this may limit administrative convenience. Users should monitor the vendor's website (https://www.totolink.net/) for future firmware updates.
More in N300rh Firmware
View allCommand injection in TOTOLINK N300RH router firmware 6.1c.1353 via setDiagnosisCfg handler. EPSS 4.0% with PoC available
CVE-2025-6400 is a critical buffer overflow vulnerability in TOTOLINK N300RH router firmware version 6.1c.1390_B20191101
OS command injection in Totolink N300RH firmware allows unauthenticated remote attackers to execute arbitrary commands t
A vulnerability classified as critical was found in TOTOLINK N300RH 6.1c.1390_B20191101. Rated medium severity (CVSS 5.3
A vulnerability classified as critical has been found in TOTOLINK N300RH 6.1c.1390_B20191101. Rated medium severity (CVS
A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. Rated medium severity (CVSS 5.3), this vulnerability i
Same weakness CWE-404 – Improper Resource Shutdown or Release
View allSame technique Denial Of Service
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2025-18807