Skip to main content

IoT CVE-2025-63624

CRITICAL
SQL Injection (CWE-89)
2026-02-03 cve@mitre.org
9.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Parameterized queries, prepared statements
MITRE ATT&CK

2 techniques across 2 tactics: Initial Access, Persistence

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS 9.8 with PoC. IoT infrastructure monitoring platforms manage utility data. SQL injection could allow manipulation of water consumption records or disruption of monitoring.

Exploit ScenarioDerived

An attacker exploits the SQL injection to access water consumption data, modify billing records, or disable monitoring alerts for water infrastructure.

Act Now Prioritize within 24-48h. Why: CRITICAL severity + public POC available.
No patch listed yet 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 12, 2026

Kede Electronics IoT smart water meter monitoring platform v1.0 has a SQL injection allowing attackers to compromise the industrial monitoring database.

Earlier versions of this analysis (1)
v1 Mar 12, 2026 - 21:54 CVSS 9.8

SQL injection in IoT water meter monitoring platform enables infrastructure database compromise.

RemediationAI

Apply patches. Isolate IoT monitoring platforms from public networks.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The Kede Electronics smart water meter monitoring platform v1.0 has a CWE-89 SQL injection that allows attackers to extract and modify data in the monitoring database.

Know when IoT gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
PoC Detected
Feb 11, 2026 - 19:25 vuln.today
Public exploit code
CVE Published
Feb 03, 2026 - 18:16 nvd
CRITICAL 9.8

DescriptionCVE.org

SQL Injection vulnerability in Shandong Kede Electronics Co., Ltd IoT smart water meter monitoring platform v.1.0 allows a remote attacker to execute arbitrary code via the imei_list.aspx file.

Executive ViewAI

Why It Matters

A critical SQL injection vulnerability (CVSS 9.8) in Shandong Kede Electronics smart water meter monitoring systems allows unauthenticated remote attackers to execute arbitrary code. Organizations operating this platform face immediate risk of complete system compromise, data breach, and operational disruption across water management infrastructure.

Business Impact: Severe
Compensating Controls

Implement Web Application Firewall (WAF) rules to detect and block SQL injection patterns in requests to imei_list.aspx; restrict network access to the vulnerable endpoint using firewall ACLs; disable or restrict the imei_list.aspx functionality if operationally feasible; segment IoT water meter devices on isolated network subnets with egress filtering; enable enhanced logging and intrusion detection for this application; consider running the platform behind a reverse proxy with input validation enforcement.

Threat Intelligence Overview

EPSS Score
0.2%
Top 52% exploitable
Exploit
POC
Public exploit code exists
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC Yes
EPSS 0.2%
Patch available No
Active threat No
Deciding rule
CRITICAL severity + public POC available
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
Poc
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
Very High

Priority Score

69
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +49
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

SQL injection exploits the way applications construct database queries by mixing user input directly into SQL statements.

Affected Products (CPE)CVE.org

cpe:2.3:o:sdkede:iot_smart_water_meter_firmware:1.0:*:*:*:*:*:*:*

More in IoT

View all
CVE-2025-45988 CRITICAL POC
9.8 Jun 13

A command injection vulnerability (CVSS 9.8). Risk factors: public PoC available.

CVE-2026-29128 CRITICAL POC
10.0 Mar 05

Plaintext daemon credentials in IDC SFX2100 routing config files (zebra, bgpd, ospfd, ripd). CVSS 10.0. PoC available.

CVE-2025-65294 CRITICAL POC
9.8 Dec 10

Remote command execution in Aqara Hub firmware (Camera Hub G3 4.1.9_0027, Hub M2 4.3.6_0027, and Hub M3 4.3.6_0025) stem

CVE-2026-101076 CRITICAL POC
9.3 Sep 28

An unauthenticated OS command injection in the CGI handler of Netcore NR289-GE firmware 1.4.5102 lets remote attackers e

CVE-2026-101077 CRITICAL POC
9.3 Sep 28

Unauthenticated network attackers can bypass authentication in the Netcore NR289-GE router's boa_temp web handler and ab

CVE-2026-101075 CRITICAL POC
9.3 Sep 28

Remote unauthenticated OS command injection in Netcore NR289-GE firmware 1.4.5102 allows attackers to execute arbitrary

CVE-2026-101072 CRITICAL POC
9.3 Sep 28

Unauthenticated OS command injection in the Netcore NR289-GE router (firmware 1.4.5102) lets any remote attacker who can

CVE-2026-101039 CRITICAL POC
9.3 Sep 28

A stack-based buffer overflow in the devdiscover service of FAST FAC1900R firmware 20190827_2.0.2 lets unauthenticated r

CVE-2026-25139 CRITICAL POC
9.1 Feb 04

RIOT IoT operating system has an out-of-bounds read vulnerability (CVSS 9.1) that could lead to information disclosure o

CVE-2026-102792 HIGH POC
8.5 Sep 29

Command injection in the Ziroom ZHOME A0101 smart-home hub (firmware 1.0.1.0) allows an attacker with high-privilege aut

CVE-2026-102793 HIGH POC
8.5 Sep 29

Authenticated command injection in Ziroom ZHOME A0101 firmware 1.0.1.0 lets a privileged user execute arbitrary operatin

CVE-2026-101261 HIGH POC
8.5 Sep 28

OS command injection in the Ziroom ZHOME A0101 smart-home device (firmware 1.0.1.0) allows an attacker who can reach the

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy