An issue was discovered in bridgetech probes VB220 IP Network Probe,VB120 Embedded IP + RF Probe, VB330 High-Capacity Probe, VB440 ST 2110 Production Analytics Probe, and NOMAD, firmware versions 6.5.0-9, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint. NOTE: the Supplier disagrees that 6.5.0-9 is affected, and instead reports that 5.6.0-3 and earlier are affected, and 5.6.0-4 (2020-09-21) and later are fixed.

AnalysisAI

An issue was discovered in bridgetech probes VB220 IP Network Probe,VB120 Embedded IP + RF Probe, VB330 High-Capacity Probe, VB440 ST 2110 Production Analytics Probe, and NOMAD, firmware versions. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Exposure of Sensitive Information (CWE-200), which allows attackers to access sensitive data that should not be disclosed. An issue was discovered in bridgetech probes VB220 IP Network Probe,VB120 Embedded IP + RF Probe, VB330 High-Capacity Probe, VB440 ST 2110 Production Analytics Probe, and NOMAD, firmware versions 6.5.0-9, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint. NOTE: the Supplier disagrees that 6.5.0-9 is affected, and instead reports that 5.6.0-3 and earlier are affected, and 5.6.0-4 (2020-09-21) and later are fixed. Affected products include: Bridgetech Vb220 Firmware, Bridgetech Vb120 Firmware, Bridgetech Vb330 Firmware, Bridgetech Vb440 Firmware, Bridgetech Nomad Portable Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Minimize information in error messages, implement proper access controls, encrypt sensitive data at rest and in transit.