Skip to main content

Maxicharger Ac Elite Business C50 Firmware CVE-2025-5825

| EUVDEUVD-2025-28667 HIGH
Security Version Number Mutable to Older Versions (CWE-1328)
2025-06-25 zdi-disclosures@trendmicro.com
7.5
CVSS 3.0 · NVD
Share

Severity by source

NVD PRIMARY
7.5 HIGH
AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Adjacent
Attack Complexity
High
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

3
EUVD ID Assigned
Mar 15, 2026 - 23:19 euvd
EUVD-2025-28667
Analysis Generated
Mar 15, 2026 - 23:19 vuln.today
CVE Published
Jun 25, 2025 - 18:15 nvd
HIGH 7.5

DescriptionCVE.org

Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.

The specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354.

AnalysisAI

CVE-2025-5825 is a firmware downgrade remote code execution vulnerability in Autel MaxiCharger AC Wallbox Commercial charging stations that allows network-adjacent attackers with Bluetooth pairing capability to execute arbitrary code by uploading a malicious firmware image without proper validation. The vulnerability has a CVSS score of 7.5 (High) with high confidentiality, integrity, and availability impact, though exploitation requires prior Bluetooth device pairing. This is a ZDI-coordinated disclosure (ZDI-CAN-26354) affecting commercial charging infrastructure.

Technical ContextAI

The vulnerability exists in the firmware update mechanism of Autel MaxiCharger AC Wallbox Commercial units, a popular commercial EV charging station platform. The root cause is classified under CWE-1328 (Inadequate Implementation of Security Features in Firmware), specifically the lack of cryptographic signature verification or integrity validation before applying firmware updates. The attack vector is Adjacent Network (AV:A), indicating the attacker must first establish Bluetooth connectivity to the device—a pairing requirement that represents a significant prerequisite. The firmware update process accepts and applies untrusted firmware images without proper authentication, allowing an attacker who has paired a malicious Bluetooth device to downgrade or replace the firmware with a compromised version containing arbitrary code execution payloads.

RemediationAI

Immediate remediation steps: (1) Apply firmware updates from Autel addressing CVE-2025-5825 once released—monitor Autel's official security advisories for patched firmware versions; (2) Interim mitigations include disabling Bluetooth pairing on units where not operationally required, implementing network segmentation to isolate charging station management interfaces, and restricting Bluetooth device pairing to authorized personnel only; (3) Review Bluetooth pairing logs and revoke any unauthorized paired devices; (4) If available, implement signed firmware update verification at the network level before devices receive updates; (5) Coordinate with Autel support for patch availability timelines and staged deployment procedures for commercial fleets. Workarounds may include air-gapping management access, disabling remote firmware update capabilities if local update remains available, and physical security controls around charging stations to prevent unauthorized Bluetooth device proximity.

CVE-2025-5830 HIGH
8.8 Jun 25

CVE-2025-5830 is a heap-based buffer overflow vulnerability in Autel MaxiCharger AC Wallbox Commercial EV chargers affec

CVE-2025-5827 HIGH
8.8 Jun 25

CVE-2025-5827 is a stack-based buffer overflow vulnerability in the ble_process_esp32_msg function of Autel MaxiCharger

CVE-2025-5822 HIGH
8.8 Jun 25

CVE-2025-5822 is a privilege escalation vulnerability in the Autel MaxiCharger AC Wallbox Commercial Technician API that

CVE-2024-23958 HIGH
8.8 Sep 28

Autel MaxiCharger AC Elite Business C50 BLE Hardcoded Credentials Authentication Bypass Vulnerability. Rated high severi

CVE-2024-23957 HIGH
8.8 Sep 28

Autel MaxiCharger AC Elite Business C50 DLB_HostHeartBeat Stack-based Buffer Overflow Remote Code Execution Vulnerabilit

CVE-2024-7795 HIGH
8.8 Aug 21

Autel MaxiCharger AC Elite Business C50 AppAuthenExchangeRandomNum Stack-Based Buffer Overflow Remote Code Execution Vul

CVE-2024-23967 HIGH
8.0 Sep 28

Autel MaxiCharger AC Elite Business C50 WebSocket Base64 Decoding Stack-based Buffer Overflow Remote Code Execution Vuln

CVE-2024-23959 HIGH
8.0 Sep 28

Autel MaxiCharger AC Elite Business C50 BLE AppChargingControl Stack-based Buffer Overflow Remote Code Execution Vulnera

CVE-2025-6678 HIGH
7.5 Jun 25

CVE-2025-6678 is an unauthenticated remote information disclosure vulnerability in Autel MaxiCharger AC Wallbox Commerci

CVE-2025-5824 HIGH
7.5 Jun 25

CVE-2025-5824 is an authentication bypass vulnerability in Autel MaxiCharger AC Wallbox Commercial that allows network-a

CVE-2025-5829 MEDIUM
6.8 Jun 25

Autel MaxiCharger AC Wallbox Commercial autocharge Stack-based Buffer Overflow Remote Code Execution Vulnerability. This

CVE-2025-5828 MEDIUM
6.8 Jun 25

Autel MaxiCharger AC Wallbox Commercial wLength Buffer Overflow Remote Code Execution Vulnerability. This vulnerability

Share

CVE-2025-5825 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy