O2 UK CVE-2025-48219
LOWVulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V14 - Data Protection Outbound data filtering
|
| Impact | CVSS score of 3.5 (LOW). Attack characteristics: network attack vector, high complexity, low privileges required, no user interaction not required. EPSS exploitation probability: 0.19%. |
| Exploit ScenarioDerived | This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the low-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Mar 28, 2026
O2 UK before 2025-05-19 allows subscribers to determine the Cell ID of other subscribers by initiating an IMS (IP Multimedia Subsystem) call and then reading the utran-cell-id-3gpp field of a. Rated low severity (CVSS 3.5), this vulnerability is remotely exploitable. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affected ProductsAI
See vendor advisory for affected versions.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-201. O2 UK before 2025-05-19 allows subscribers to determine the Cell ID of other subscribers by initiating an IMS (IP Multimedia Subsystem) call and then reading the utran-cell-id-3gpp field of a Cellular-Network-Info SIP header, aka an ECI (E-UTRAN Cell Identity) leak. The Cell ID might be usable to identify a cell location via crowdsourced data, and might correspond to a small physical area (e.g., if the called party is in a city centre). Removal of the Cellular-Network-Info header is mentioned in section 4.4.19 of ETSI TS 124 229. Version information: before 2025.
Know when the next one hits your stack
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:H/PR:L/UI:N/S:C/C:L/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionCVE.org
O2 UK before 2025-05-19 allows subscribers to determine the Cell ID of other subscribers by initiating an IMS (IP Multimedia Subsystem) call and then reading the utran-cell-id-3gpp field of a Cellular-Network-Info SIP header, aka an ECI (E-UTRAN Cell Identity) leak. The Cell ID might be usable to identify a cell location via crowdsourced data, and might correspond to a small physical area (e.g., if the called party is in a city centre). Removal of the Cellular-Network-Info header is mentioned in section 4.4.19 of ETSI TS 124 229.
Executive ViewAI
CVE-2025-48219 is a low-severity vulnerability in O2 UK before 2025-05-19 (CVSS 3.5). The limited severity suggests constrained impact, typically requiring specific conditions or local access for exploitation. Apply vendor updates when available as part of routine maintenance.
Apply vendor patch during routine maintenance. Standard security controls provide adequate interim protection.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
GitHub PoC
Exploit-DB