Skip to main content

F5Os A CVE-2025-36546

CRITICAL
Incorrect Authorization (CWE-863)
2025-05-07 f5sirt@f5.com
9.2
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
9.2 CRITICAL
CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
High
Privileges Required
None
User Interaction
None
Scope
X

Lifecycle Timeline

2
Analysis Generated
Mar 28, 2026 - 18:40 vuln.today
CVE Published
May 07, 2025 - 22:15 nvd
CRITICAL 9.2

DescriptionCVE.org

On an F5OS system, if the root user had previously configured the system to allow login via SSH key-based authentication, and then enabled Appliance Mode; access via SSH key-based authentication is still allowed. For an attacker to exploit this vulnerability they must obtain the root user's SSH private key.

Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.

AnalysisAI

On an F5OS system, if the root user had previously configured the system to allow login via SSH key-based authentication, and then enabled Appliance Mode; access via SSH key-based authentication is. Rated critical severity (CVSS 9.2), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Incorrect Authorization (CWE-863), which allows attackers to bypass authorization checks to access restricted resources. On an F5OS system, if the root user had previously configured the system to allow login via SSH key-based authentication, and then enabled Appliance Mode; access via SSH key-based authentication is still allowed. For an attacker to exploit this vulnerability they must obtain the root user's SSH private key. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated. Affected products include: F5 F5Os-A, F5 F5Os-C.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Review and test authorization logic, implement consistent access control checks, use centralized authorization framework.

Share

CVE-2025-36546 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy