Skip to main content

Virtual Appliance Application CVE-2025-34200

HIGH
Cleartext Storage of Sensitive Information (CWE-312)
2025-09-19 disclosure@vulncheck.com
8.6
CVSS 4.0 · NVD
Share

Severity by source

NVD PRIMARY
8.6 HIGH
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Local
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
X

Lifecycle Timeline

3
Analysis Generated
Mar 28, 2026 - 19:13 vuln.today
PoC Detected
Sep 24, 2025 - 19:18 vuln.today
Public exploit code
CVE Published
Sep 19, 2025 - 19:15 nvd
HIGH 8.6

DescriptionCVE.org

Vasion Print (formerly PrinterLogic) Virtual Appliance Host and Application (VA and SaaS deployments) provision the appliance with the network account credentials in clear-text inside /etc/issue, and the file is world-readable by default. An attacker with local shell access can read /etc/issue to obtain the network account username and password. Using the network account an attacker can change network parameters via the appliance interface, enabling local misconfiguration, network disruption or further escalation depending on deployment.

AnalysisAI

Vasion Print (formerly PrinterLogic) Virtual Appliance Host and Application (VA and SaaS deployments) provision the appliance with the network account credentials in clear-text inside /etc/issue, and. Rated high severity (CVSS 8.6), this vulnerability is no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-312. Vasion Print (formerly PrinterLogic) Virtual Appliance Host and Application (VA and SaaS deployments) provision the appliance with the network account credentials in clear-text inside /etc/issue, and the file is world-readable by default. An attacker with local shell access can read /etc/issue to obtain the network account username and password. Using the network account an attacker can change network parameters via the appliance interface, enabling local misconfiguration, network disruption or further escalation depending on deployment. Affected products include: Vasion Virtual Appliance Application, Vasion Virtual Appliance Host.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2025-34200 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy