CVE-2025-32828

HIGH
2025-04-16 [email protected]
8.7
CVSS 4.0
Share

CVSS Vector

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

2
Analysis Generated
Mar 28, 2026 - 18:37 vuln.today
CVE Published
Apr 16, 2025 - 18:16 nvd
HIGH 8.7

Description

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Analysis

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical Context

This vulnerability is classified as SQL Injection (CWE-89), which allows attackers to execute arbitrary SQL commands against the database. A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. Affected products include: Siemens Telecontrol Server Basic.

Affected Products

Siemens Telecontrol Server Basic.

Remediation

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized queries/prepared statements. Never concatenate user input into SQL. Apply least-privilege database permissions.

Priority Score

44