Siemens
CVE-2025-29999
MEDIUM
Severity by source
CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Lifecycle Timeline
2DescriptionCVE.org
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). The affected application searches for executable files in the application folder without proper validation. This could allow an attacker to execute arbitrary code with administrative privileges by placing a malicious executable in the same directory.
AnalysisAI
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). Rated medium severity (CVSS 5.4). No vendor patch available.
Technical ContextAI
This vulnerability is classified as Improper Privilege Management (CWE-269), which allows attackers to escalate privileges to gain unauthorized elevated access. A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). The affected application searches for executable files in the application folder without proper validation. This could allow an attacker to execute arbitrary code with administrative privileges by placing a malicious executable in the same directory.
Affected ProductsAI
See vendor advisory for affected versions.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply principle of least privilege, validate privilege transitions, implement proper role separation.
Remote code execution in Windows Shell across XP through Windows 7 via malicious .LNK or .PIF shortcut files automatical
Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x
Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via craf
AscoServer.exe in the server in Siemens SiPass integrated MP2.6 and earlier does not properly handle IOCP RPC messages r
Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denial of service (device
Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed
Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3
Buffer overflow in the integrated web server on Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WI
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) befor
Same weakness CWE-269 – Improper Privilege Management
View allShare
External POC / Exploit Code