Skip to main content

Honeywell CVE-2025-2520

| EUVDEUVD-2025-21068 HIGH
Use of Uninitialized Variable (CWE-457)
2025-07-10 psirt@honeywell.com
7.5
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

3
EUVD ID Assigned
Mar 16, 2026 - 06:52 euvd
EUVD-2025-21068
Analysis Generated
Mar 16, 2026 - 06:52 vuln.today
CVE Published
Jul 10, 2025 - 20:15 nvd
HIGH 7.5

DescriptionCVE.org

The Honeywell Experion PKS contains an Uninitialized Variable in the common Epic Platform Analyzer (EPA) communications. An attacker could potentially exploit this vulnerability, leading to a Communication Channel Manipulation, which results in a dereferencing of an uninitialized pointer leading to a denial of service.

Honeywell recommends updating to the most recent version of

Honeywell Experion PKS: 520.2 TCU9 HF1and 530.1 TCU3 HF1. The affected Experion PKS products are

C300 PCNT02, EHB, EHPM, ELMM, Classic ENIM, ETN, FIM4, FIM8, PGM, and RFIM. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.

AnalysisAI

CVE-2025-2520 is an uninitialized variable vulnerability in Honeywell Experion PKS's Epic Platform Analyzer (EPA) communications module that enables remote attackers to manipulate communication channels and trigger pointer dereference errors, resulting in denial of service. The vulnerability affects multiple Experion PKS product lines across versions 520.1-520.2 TCU9 and 530-530 TCU3, with a CVSS score of 7.5 indicating high availability impact. No evidence of active exploitation (KEV status) or public POC availability is indicated; however, the network-accessible attack vector and lack of authentication requirements elevate real-world risk for critical industrial control environments.

Technical ContextAI

The vulnerability resides in the Epic Platform Analyzer (EPA) communications subsystem of Honeywell Experion PKS, a distributed process control system used in industrial automation. The root cause is classified under CWE-457 (Use of Uninitialized Variable), where the EPA communications handler fails to initialize a variable before use in the common communication protocol stack. When an attacker sends a specially crafted network packet to the EPA communications interface, the uninitialized variable is dereferenced within the channel manipulation logic, causing a null or garbage pointer dereference. This occurs in the communication channel state machine, which processes incoming requests without proper input validation or variable initialization checks. The affected products include C300 PCNT02, EHB, EHPM, ELMM, Classic ENIM, ETN, FIM4, FIM8, PGM, and RFIM modules, all of which implement the compromised EPA protocol handler. The vulnerability is network-exploitable (AV:N) with low attack complexity (AC:L) and requires no prior authentication (PR:N) or user interaction (UI:N), making it accessible to unauthenticated remote adversaries.

RemediationAI

Immediate action: upgrade to patched versions Honeywell Experion PKS 520.2 TCU9 HF1 or 530.1 TCU3 HF1 depending on your installed version. Before patching, implement network-level mitigations: (1) restrict network access to EPA communication ports using firewall rules to only trusted engineering workstations and control systems; (2) implement network segmentation to isolate Experion PKS systems from untrusted networks; (3) disable EPA communications if not in active use. Post-patch validation: test communication channel integrity after upgrade to verify EPA stability. For organizations unable to patch immediately, apply compensating controls via industrial firewalls to block unexpected EPA protocol traffic and monitor for abnormal communication patterns. Honeywell's official security advisory should be consulted for detailed patch deployment procedures and any additional workarounds specific to your configuration.

CVE-2013-0108 MEDIUM POC
6.8 Feb 24

An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R

CVE-2015-0984 CRITICAL POC
10.0 Mar 31

Directory traversal vulnerability in the FTP server on Honeywell Excel Web XL1000C50 52 I/O, XL1000C100 104 I/O, XL1000C

CVE-2023-3710 CRITICAL POC
9.8 Sep 12

Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injec

CVE-2017-14263 HIGH
8.1 Sep 11

Honeywell NVR devices allow remote attackers to create a user account in the admin group by leveraging access to a guest

CVE-2017-5671 HIGH POC
8.8 Mar 29

Honeywell Intermec PM23, PM42, PM43, PC23, PC43, PD43, and PC42 industrial printers before 10.11.013310 and 10.12.x befo

CVE-2014-8269 HIGH
7.5 Dec 13

Multiple stack-based buffer overflows in (1) HWOPOSScale.ocx and (2) HWOPOSSCANNER.ocx in Honeywell OPOS Suite before 1.

CVE-2025-2605 CRITICAL
9.9 May 02

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB

CVE-2026-3611 CRITICAL
10.0 Mar 12

Unauthenticated access to Honeywell IQ4x building controller HMI. CVSS 10.0.

CVE-2017-5140 CRITICAL
9.8 Feb 13

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-

CVE-2017-5139 CRITICAL
9.8 Feb 13

An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-

CVE-2023-25178 CRITICAL
9.8 Jul 13

Controller may be loaded with malicious firmware which could enable remote code execution. Rated critical severity (CVSS

CVE-2022-30318 CRITICAL
9.8 Aug 31

Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. Rated critical severity (CVSS 9.8), this vulnerability

Share

CVE-2025-2520 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy