Skip to main content

Sangfor Operation CVE-2025-12916

LOW
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') (CWE-74)
2025-11-09 cna@vuldb.com
2.1
CVSS 4.0 · NVD

Severity by source

NVD PRIMARY
2.1 LOW
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

5
Severity Changed
Apr 29, 2026 - 01:11 NVD
MEDIUM LOW
CVSS changed
Apr 29, 2026 - 01:11 NVD
5.3 (MEDIUM) 2.1 (LOW)
Analysis Generated
Mar 28, 2026 - 19:21 vuln.today
PoC Detected
Dec 09, 2025 - 21:48 vuln.today
Public exploit code
CVE Published
Nov 09, 2025 - 00:15 nvd
MEDIUM 5.3

DescriptionCVE.org

A vulnerability was determined in Sangfor Operation and Maintenance Security Management System 3.0. Impacted is an unknown function of the file /fort/portal_login of the component Frontend. This manipulation of the argument loginUrl causes command injection. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. Upgrading to version 3.0.11 and 3.0.12 is recommended to address this issue. It is advisable to upgrade the affected component.

AnalysisAI

A vulnerability was determined in Sangfor Operation and Maintenance Security Management System 3.0. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-74. A vulnerability was determined in Sangfor Operation and Maintenance Security Management System 3.0. Impacted is an unknown function of the file /fort/portal_login of the component Frontend. This manipulation of the argument loginUrl causes command injection. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. Upgrading to version 3.0.11 and 3.0.12 is recommended to address this issue. It is advisable to upgrade the affected component. Affected products include: Sangfor Operation And Maintenance Security Management System. Version information: version 3.0.11.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2025-12916 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy