Skip to main content

CVE-2025-10541

HIGH
Incorrect Permission Assignment for Critical Resource (CWE-732)
2025-09-25 551230f0-3615-47bd-b7cc-93e92e730bbf
7.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.8 HIGH
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
Analysis Generated
Mar 28, 2026 - 19:14 vuln.today
CVE Published
Sep 25, 2025 - 15:16 nvd
HIGH 7.8

DescriptionCVE.org

iMonitor EAM 9.6394 installs a system service (eamusbsrv64.exe) that runs with NT AUTHORITY\SYSTEM privileges. This service includes an insecure update mechanism that automatically loads files placed in the C:\sysupdate\ directory during startup. Because any local user can create and write to this directory, an attacker can place malicious DLLs or executables in it. Upon service restart, the files are moved to the application’s installation path and executed with SYSTEM privileges, leading to privilege escalation.

AnalysisAI

iMonitor EAM 9.6394 installs a system service (eamusbsrv64.exe) that runs with NT AUTHORITY\SYSTEM privileges. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Incorrect Permission Assignment (CWE-732), which allows attackers to access resources due to misconfigured permissions. iMonitor EAM 9.6394 installs a system service (eamusbsrv64.exe) that runs with NT AUTHORITY\SYSTEM privileges. This service includes an insecure update mechanism that automatically loads files placed in the C:\sysupdate\ directory during startup. Because any local user can create and write to this directory, an attacker can place malicious DLLs or executables in it. Upon service restart, the files are moved to the application’s installation path and executed with SYSTEM privileges, leading to privilege escalation.

Affected ProductsAI

See vendor advisory for affected versions.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Review and restrict file/resource permissions, apply principle of least privilege.