Factorytalk Assetcentre
CVE-2025-0477
CRITICAL
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V6 - Authentication Credential protection in transit/storage
|
| Impact | CVSS score of 9.3 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. EPSS exploitation probability: 1.50%. |
| Exploit ScenarioDerived | A remote attacker could obtain user credentials due to weak protection mechanisms by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Mar 28, 2026
An encryption vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. Rated critical severity (CVSS 9.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Hash passwords with strong algorithms (bcrypt, argon2), encrypt credentials in transit and at rest, never log credentials.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Insufficiently Protected Credentials (CWE-522), which allows attackers to obtain user credentials due to weak protection mechanisms. An encryption vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to a weak encryption methodology and could allow a threat actor to extract passwords belonging to other users of the application. Affected products include: Rockwellautomation Factorytalk Assetcentre.
Know when Factorytalk Assetcentre gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionCVE.org
An encryption vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to a weak encryption methodology and could allow a threat actor to extract passwords belonging to other users of the application.
Executive ViewAI
Organizations using all face critical risk from CVE-2025-0477 rated CVSS 9.3. Successful exploitation could critically impact the confidentiality, integrity, and availability of affected systems. Organizations should apply vendor updates immediately when available and implement compensating controls in the interim.
Apply vendor patch. If immediate patching is not feasible: (1) Implement network-level access controls to limit exposure; (2) Enable enhanced monitoring and alerting; (3) Apply principle of least privilege.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)CVE.org
More in Factorytalk Assetcentre
View allA data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre
A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre
GitHub PoC
Exploit-DB