Factorytalk Policy Manager CVE-2024-6326

LOW
Improper Privilege Management (CWE-269)
2024-07-16 PSIRT@rockwellautomation.com
1.8
CVSS 4.0 · Vendor: rockwellautomation

Severity by source

Vendor (rockwellautomation) PRIMARY
1.8 LOW
CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:A/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from Vendor (rockwellautomation) · only source for this CVE.

CVSS VectorVendor: rockwellautomation

CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:A/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
A
Scope
X

Lifecycle Timeline

1
CVE Published
Jul 16, 2024 - 17:15 cve.org
LOW 1.8

DescriptionCVE.org

An exposure of sensitive information vulnerability exists in the Rockwell Automation FactoryTalk® System Service. A malicious user could exploit this vulnerability by starting a back-up or restore process, which temporarily exposes private keys, passwords, pre-shared keys, and database folders when they are temporarily copied to an interim folder. This vulnerability is due to the lack of explicit permissions set on the backup folder. If private keys are obtained by a malicious user, they could impersonate resources on the secured network.

AnalysisAI

An exposure of sensitive information vulnerability exists in the Rockwell Automation FactoryTalk® System Service. Rated low severity (CVSS 1.8), this vulnerability is low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Improper Privilege Management (CWE-269), which allows attackers to escalate privileges to gain unauthorized elevated access. An exposure of sensitive information vulnerability exists in the Rockwell Automation FactoryTalk® System Service. A malicious user could exploit this vulnerability by starting a back-up or restore process, which temporarily exposes private keys, passwords, pre-shared keys, and database folders when they are temporarily copied to an interim folder. This vulnerability is due to the lack of explicit permissions set on the backup folder. If private keys are obtained by a malicious user, they could impersonate resources on the secured network. Affected products include: Rockwellautomation Factorytalk Policy Manager, Rockwellautomation Factorytalk System Services.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply principle of least privilege, validate privilege transitions, implement proper role separation.