Skip to main content

W18E Firmware CVE-2024-46430

MEDIUM
Improper Access Control (CWE-284)
2025-02-10 cve@mitre.org
6.5
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Access control enforcement
MITRE ATT&CK

1 technique across 1 tactic: Defense Evasion

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 6.5 (MEDIUM). Attack characteristics: adjacent network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available. EPSS exploitation probability: 0.10%.

Exploit ScenarioDerived

Successful exploitation could compromise the medium-severity affected system.

This Week Schedule remediation this week. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 28, 2026

Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. Rated medium severity (CVSS 6.5), this vulnerability is no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-284. Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. Unauthorized password change via the web management portal allows an unauthenticated remote attacker to change the administrator password by sending a specially crafted HTTP POST request to the setLoginPassword function, bypassing the authentication mechanism. Affected products include: Tenda W18E Firmware.

Know when W18E Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 6.5 MEDIUM
AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
High
Availability
None

Lifecycle Timeline

2
PoC Detected
Mar 25, 2025 - 18:12 vuln.today
Public exploit code
CVE Published
Feb 10, 2025 - 19:15 nvd
MEDIUM 6.5

DescriptionCVE.org

Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. Unauthorized password change via the web management portal allows an unauthenticated remote attacker to change the administrator password by sending a specially crafted HTTP POST request to the setLoginPassword function, bypassing the authentication mechanism.

Executive ViewAI

Why It Matters

CVE-2024-46430 presents notable security risk, a improper access control vulnerability rated CVSS 6.5. Exploitation could compromise the security of affected deployments. Proof-of-concept code is publicly available. Organizations should apply vendor updates when available and monitor for exploitation.

Business Impact: Moderate
Compensating Controls

Apply vendor patch. If patching is delayed: restrict network access and enable monitoring.

Threat Intelligence Overview

EPSS Score
0.1%
Top 73% exploitable
Exploit
POC
Public exploit code exists

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC Yes
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

Exploitation· derived
Poc
System Exposure· derived
Controlled
Automatable· derived
No

Priority Score

52
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +32
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

Affected Products (CPE)CVE.org

cpe:2.3:o:tenda:w18e_firmware:16.01.0.8\(1625\):*:*:*:*:*:*:*
CVE-2025-45343 CRITICAL POC
9.8 May 28

An issue in Tenda W18E v.2.0 v.16.01.0.11 allows an attacker to execute arbitrary code via the editing functionality of

CVE-2023-46370 CRITICAL POC
9.8 Oct 25

Tenda W18E V16.01.0.8(1576) has a command injection vulnerability via the hostName parameter in the formSetNetCheckTools

CVE-2023-46369 CRITICAL POC
9.8 Oct 25

Tenda W18E V16.01.0.8(1576) contains a stack overflow vulnerability via the portMirrorMirroredPorts parameter in the for

CVE-2024-46435 HIGH POC
8.0 Feb 10

A stack overflow vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an authenticated remote a

CVE-2025-29217 MEDIUM POC
6.5 Mar 20

Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiSSID parameter at /goform/setModules.

CVE-2025-29218 MEDIUM POC
6.5 Mar 20

Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiPwd parameter at /goform/setModules. R

CVE-2024-46437 MEDIUM POC
6.5 Feb 10

A sensitive information disclosure vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an unau

CVE-2025-3203 MEDIUM
5.3 Apr 04

A vulnerability classified as problematic was found in Tenda W18E 16.01.0.11. Rated medium severity (CVSS 5.3), this vul

CVE-2024-46436 HIGH POC
8.3 Feb 10

Hardcoded credentials in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to gain root access to the

CVE-2024-46434 HIGH POC
8.8 Feb 10

Tenda W18E V16.01.0.8(1625) suffers from authentication bypass in the web management portal allowing an unauthorized rem

CVE-2024-46433 HIGH POC
8.8 Feb 10

A default credentials vulnerability in Tenda W18E V16.01.0.8(1625) allows unauthenticated remote attackers to access the

CVE-2024-46432 HIGH POC
8.8 Feb 10

Tenda W18E V16.01.0.8(1625) is vulnerable to Incorrect Access Control. Rated high severity (CVSS 8.8), this vulnerabilit

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy