Skip to main content

Electron Builder CVE-2024-39698

HIGH
Improper Neutralization of Variable Name Delimiters (CWE-154)
2024-07-09 security-advisories@github.com
7.5
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.5 HIGH
AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
High
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Jul 09, 2024 - 18:15 nvd
HIGH 7.5

DescriptionNVD

electron-updater allows for automatic updates for Electron apps. The file packages/electron-updater/src/windowsExecutableCodeSignatureVerifier.ts implements the signature validation routine for Electron applications on Windows. Because of the surrounding shell, a first pass by cmd.exe expands any environment variable found in command-line above. This creates a situation where verifySignature() can be tricked into validating the certificate of a different file than the one that was just downloaded. If the step is successful, the malicious update will be executed even if its signature is invalid. This attack assumes a compromised update manifest (server compromise, Man-in-the-Middle attack if fetched over HTTP, Cross-Site Scripting to point the application to a malicious updater server, etc.). The patch is available starting from 6.3.0-alpha.6.

AnalysisAI

electron-updater allows for automatic updates for Electron apps. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required. Public exploit code available.

Technical ContextAI

This vulnerability is classified under CWE-154. electron-updater allows for automatic updates for Electron apps. The file packages/electron-updater/src/windowsExecutableCodeSignatureVerifier.ts implements the signature validation routine for Electron applications on Windows. Because of the surrounding shell, a first pass by cmd.exe expands any environment variable found in command-line above. This creates a situation where verifySignature() can be tricked into validating the certificate of a different file than the one that was just downloaded. If the step is successful, the malicious update will be executed even if its signature is invalid. This attack assumes a compromised update manifest (server compromise, Man-in-the-Middle attack if fetched over HTTP, Cross-Site Scripting to point the application to a malicious updater server, etc.). The patch is available starting from 6.3.0-alpha.6. Affected products include: Electron Electron-Builder.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2024-39698 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy