Skip to main content

Medicalis Workflow Orchestrator CVE-2024-37999

HIGH
Improper Ownership Management (CWE-282)
2024-07-08 productcert@siemens.com
8.5
CVSS 4.0 · Vendor: siemens
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V8 - Authorization Ownership management
Impact

CVSS score of 8.5 (HIGH). Attack characteristics: local attack vector, low complexity, low privileges required, no user interaction not required.

Exploit ScenarioDerived

Successful exploitation could compromise the high-severity affected system.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

A vulnerability has been identified in Medicalis Workflow Orchestrator (All versions). Rated high severity (CVSS 8.5), this vulnerability is low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-282. A vulnerability has been identified in Medicalis Workflow Orchestrator (All versions). The affected application executes as a trusted account with high privileges and network access. This could allow an authenticated local attacker to escalate privileges. Affected products include: Siemens Medicalis Workflow Orchestrator.

Know when Medicalis Workflow Orchestrator gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (siemens) PRIMARY 8.5 HIGH
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (siemens) · only source for this CVE.

CVSS VectorVendor: siemens

Attack Vector
Local
Attack Complexity
Low
Attack Requirements
None
Privileges Required
Low
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

DescriptionCVE.org

A vulnerability has been identified in Medicalis Workflow Orchestrator (All versions). The affected application executes as a trusted account with high privileges and network access. This could allow an authenticated local attacker to escalate privileges.

Threat Intelligence Overview

EPSS Score
0.1%
Top 96% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Defer
Exploitation· derived
None
System Exposure· derived
Small
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

42
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +42
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Privilege escalation occurs when an attacker leverages flaws in access control mechanisms to gain permissions beyond what they were originally granted.

Affected Products (CPE)CVE.org

cpe:2.3:a:siemens:medicalis_workflow_orchestrator:*:*:*:*:*:*:*:*

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy