CVE-2024-13985

CRITICAL
2025-08-27 [email protected]
10.0
CVSS 4.0
Share

CVSS Vector

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
X

Lifecycle Timeline

2
Analysis Generated
Mar 28, 2026 - 19:09 vuln.today
CVE Published
Aug 27, 2025 - 22:15 nvd
CRITICAL 10.0

Description

A command injection vulnerability in Dahua EIMS versions prior to 2240008 allows unauthenticated remote attackers to execute arbitrary system commands via the capture_handle.action interface. The flaw stems from improper input validation in the captureCommand parameter, which is processed without sanitization or authentication. By sending crafted HTTP requests, attackers can inject OS-level commands that are executed on the server, leading to full system compromise. Exploitation evidence was first observed by the Shadowserver Foundation on 2024-04-06 UTC.

Analysis

A command injection vulnerability in Dahua EIMS versions prior to 2240008 allows unauthenticated remote attackers to execute arbitrary system commands via the capture_handle.action interface. Rated critical severity (CVSS 10.0), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical Context

This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. A command injection vulnerability in Dahua EIMS versions prior to 2240008 allows unauthenticated remote attackers to execute arbitrary system commands via the capture_handle.action interface. The flaw stems from improper input validation in the captureCommand parameter, which is processed without sanitization or authentication. By sending crafted HTTP requests, attackers can inject OS-level commands that are executed on the server, leading to full system compromise. Exploitation evidence was first observed by the Shadowserver Foundation on 2024-04-06 UTC. Version information: prior to 2240008.

Affected Products

Dahua EIMS versions.

Remediation

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.

Priority Score

50
Low Medium High Critical
KEV: 0
EPSS: +0.3
CVSS: +50
POC: 0

Share

CVE-2024-13985 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy