Skip to main content

Ragflow CVE-2024-12869

MEDIUM
Missing Authentication for Critical Function (CWE-306)
2025-03-20 security@huntr.dev
4.3
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
4.3 MEDIUM
AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
Low
Integrity
None
Availability
None

Lifecycle Timeline

3
Analysis Generated
Mar 28, 2026 - 18:32 vuln.today
PoC Detected
Oct 15, 2025 - 13:15 vuln.today
Public exploit code
CVE Published
Mar 20, 2025 - 10:15 nvd
MEDIUM 4.3

DescriptionCVE.org

In infiniflow/ragflow version v0.12.0, there is an improper authentication vulnerability that allows a user to view another user's invite list. This can lead to a privacy breach where users' personal or private information, such as email addresses or usernames in the invite list, could be exposed without their consent. This data leakage can facilitate further attacks, such as phishing or spam, and result in loss of trust and potential regulatory issues.

AnalysisAI

In infiniflow/ragflow version v0.12.0, there is an improper authentication vulnerability that allows a user to view another user's invite list. Rated medium severity (CVSS 4.3), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Missing Authentication for Critical Function (CWE-306), which allows attackers to access critical functionality without authentication. In infiniflow/ragflow version v0.12.0, there is an improper authentication vulnerability that allows a user to view another user's invite list. This can lead to a privacy breach where users' personal or private information, such as email addresses or usernames in the invite list, could be exposed without their consent. This data leakage can facilitate further attacks, such as phishing or spam, and result in loss of trust and potential regulatory issues. Affected products include: Infiniflow Ragflow.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Require authentication for all sensitive operations, implement defense in depth.

Share

CVE-2024-12869 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy