Skip to main content

Sgima Lite Lite Firmware CVE-2023-4667

MEDIUM
Cross-site Scripting (XSS) (CWE-79)
2023-11-28 a87f365f-9d39-4848-9b3a-58c7cae69cab
4.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
4.8 MEDIUM
AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
High
User Interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
Low
Availability
None

Lifecycle Timeline

1
CVE Published
Nov 28, 2023 - 09:15 nvd
MEDIUM 4.8

DescriptionNVD

The web interface of the PAC Device allows the device administrator user profile to store malicious scripts in some fields. The stored malicious script is then executed when the GUI is opened by any users of the webserver administration interface.

The root cause of the vulnerability is inadequate input validation and output encoding in the web administration interface component of the firmware.

This could lead to  unauthorized access and data leakage

AnalysisAI

The web interface of the PAC Device allows the device administrator user profile to store malicious scripts in some fields. Rated medium severity (CVSS 4.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. The web interface of the PAC Device allows the device administrator user profile to store malicious scripts in some fields. The stored malicious script is then executed when the GUI is opened by any users of the webserver administration interface. The root cause of the vulnerability is inadequate input validation and output encoding in the web administration interface component of the firmware. This could lead to unauthorized access and data leakage Affected products include: Idemia Sgima Lite \& Lite\+ Firmware, Idemia Sigma Wide Firmware, Idemia Sigma Extreme Firmware, Idemia Morphowave Compact Firmware, Idemia Morphowave Sp Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.

Share

CVE-2023-4667 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy