Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Output encoding, context-aware escaping
MITRE ATT&CK
2 techniques across 2 tactics: Initial Access, Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 5.4 (MEDIUM). Attack characteristics: network attack vector, low complexity, low privileges required, user interaction required. EPSS exploitation probability: 0.11%. |
| Exploit ScenarioDerived | A remote attacker could inject malicious scripts into web pages viewed by other users by sending crafted requests to the affected application. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Mar 28, 2026
IBM Sterling Control Center 6.2.1, 6.3.1, and 6.4.0 is vulnerable to cross-site scripting. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Earlier versions of this analysis (1)
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. IBM Sterling Control Center 6.2.1, 6.3.1, and 6.4.0 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session. Affected products include: Ibm Sterling Control Center.
Know when Sterling Control Center gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionCVE.org
IBM Sterling Control Center 6.2.1, 6.3.1, and 6.4.0 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session.
Executive ViewAI
CVE-2023-42007 presents moderate security risk, a cross-site scripting vulnerability rated CVSS 5.4. Attackers could inject scripts to steal sessions or perform actions as authenticated users. Organizations should apply vendor updates when available and monitor for exploitation.
Apply vendor patch. If patching is delayed: implement CSP headers, enable HttpOnly cookies, deploy WAF XSS rules.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Cross-Site Scripting occurs when an application accepts untrusted data and sends it to a web browser without proper validation or encoding.
Affected Products (CPE)CVE.org
More in Sterling Control Center
View allAn unspecified buffer-read method in IBM Sterling Control Center (SCC) 5.2 before 5.2.0.9, 5.3 before 5.3.0.4, and 5.4 t
IBM Control Center 6.2.1 through 6.3.1 is vulnerable to HTTP header injection, caused by improper validation of input by
IBM Control Center 6.x before 6.0.0.1 iFix06 and Sterling Control Center 5.4.x before 5.4.2.1 iFix09 allow local users t
IBM Sterling Control Center 6.2.1, 6.3.1, and 6.4.0 allows web pages to be stored locally which can be read by another u
Cross-site scripting (XSS) vulnerability in IBM Sterling Control Center (SCC) 5.2 before 5.2.0.9, 5.3 before 5.3.0.4, an
Open redirect vulnerability in IBM Sterling Control Center 5.4.0 before 5.4.0.1 iFix 3 and 5.4.1 before 5.4.1.0 iFix 2 a
NVD
CVE.org
EPSS
GitHub PoC