Sinema Server
CVE-2023-35796
CRITICAL
Severity by source
AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with SYSTEM privileges on the application server. (ZDI-CAN-19823)
AnalysisAI
A vulnerability has been identified in SINEMA Server V14 (All versions). Rated critical severity (CVSS 9.0), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with SYSTEM privileges on the application server. (ZDI-CAN-19823) Affected products include: Siemens Sinema Server.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.
More in Sinema Server
View allA crafted request uri-path can cause mod_proxy to forward the request to an origin server choosen by the remote user.4.4
ap_escape_quotes() may write beyond the end of a buffer when given malicious input. Rated critical severity (CVSS 9.8),
Multiple unspecified vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote at
Siemens SINEMA Server uses weak permissions for the application folder, which allows local users to gain privileges via
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515
Malformed requests may cause the server to dereference a NULL pointer.4.48 and earlier. Rated high severity (CVSS 7.5),
A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3), SIN
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. Rated med
Siemens SINEMA Server before 12 SP1 allows remote attackers to cause a denial of service (web-interface outage) via craf
Same weakness CWE-79 – Cross-site Scripting (XSS)