Sel 2241 Rtac Module Firmware
CVE-2023-31158
MEDIUM
Severity by source
AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
Lifecycle Timeline
1DescriptionNVD
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code.
See SEL Service Bulletin dated 2022-11-15 for more details.
AnalysisAI
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. Affected products include: Selinc Sel-2241 Rtac Module Firmware, Selinc Sel-3350 Firmware, Selinc Sel-3505 Firmware, Selinc Sel-3505-3 Firmware, Selinc Sel-3530 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.
An Authentication Bypass Using an Alternate Path or Channel vulnerability in the Schweitzer Engineering Laboratories Rea
An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (S
An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (S
A Storing Passwords in a Recoverable Format vulnerability in the Schweitzer Engineering Laboratories Real-Time Automatio
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer
Same weakness CWE-79 – Cross-site Scripting (XSS)
View allShare
External POC / Exploit Code
Leaving vuln.today