Nios
CVE-2022-28975
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Output encoding, context-aware escaping
MITRE ATT&CK
2 techniques across 2 tactics: Initial Access, Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 5.4 (MEDIUM). Attack characteristics: network attack vector, low complexity, low privileges required, user interaction required. Public proof-of-concept exploit code is available. EPSS exploitation probability: 0.18%. |
| Exploit ScenarioDerived | A remote attacker could inject malicious scripts into web pages viewed by other users by sending crafted requests to the affected application. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Mar 28, 2026
A stored cross-site scripting (XSS) vulnerability in Infoblox NIOS v8.5.2-409296 allows attackers to execute arbitrary web scripts or HTML via a crafted payload injected into the VLAN View Name field. Rated medium severity (CVSS 5.4), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
Earlier versions of this analysis (1)
A stored cross-site scripting (XSS) vulnerability in Infoblox NIOS v8.5.2-409296 allows attackers to execute arbitrary web scripts or HTML via a crafted payload injected into the VLAN View Name field.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. A stored cross-site scripting (XSS) vulnerability in Infoblox NIOS v8.5.2-409296 allows attackers to execute arbitrary web scripts or HTML via a crafted payload injected into the VLAN View Name field. Affected products include: Infoblox Nios.
Know when Nios gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
2DescriptionNVD
A stored cross-site scripting (XSS) vulnerability in Infoblox NIOS v8.5.2-409296 allows attackers to execute arbitrary web scripts or HTML via a crafted payload injected into the VLAN View Name field.
Executive ViewAI
Organizations using Infoblox NIOS should be aware of moderate risk from CVE-2022-28975, a cross-site scripting vulnerability rated CVSS 5.4. Attackers could inject scripts to steal sessions or perform actions as authenticated users. Proof-of-concept code is publicly available. Organizations should apply vendor updates when available and monitor for exploitation.
Apply vendor patch. If patching is delayed: implement CSP headers, enable HttpOnly cookies, deploy WAF XSS rules.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Cross-Site Scripting occurs when an application accepts untrusted data and sends it to a web browser without proper validation or encoding.
Affected Products (CPE)NVD
Infoblox NIOS through 8.6.4 and 9.x through 9.0.3 has Improper Input Validation. Rated critical severity (CVSS 9.8), thi
Infoblox NIOS through 8.6.4 executes with more privileges than required. Rated critical severity (CVSS 9.8), this vulner
Infoblox NIOS through 8.6.4 has Improper Authentication for Grids. Rated critical severity (CVSS 9.8), this vulnerabilit
Infoblox NIOS through 8.6.4 has Improper Access Control for Grids. Rated critical severity (CVSS 9.1), this vulnerabilit
Argument injection in Infoblox NIOS troubleshooting commands allows an authenticated high-privilege administrator to esc
In Infoblox NIOS through 9.0.7, insecure deserialization can result in remote code execution. [CVSS 8.8 HIGH]
Infoblox NIOS through 8.5.1 has a faulty component that accepts malicious input without sanitization, resulting in shell
In Infoblox NIOS through 9.0.7, a High-Privileged User Can Trigger an Arbitrary File Write via the Account Creation Mech
Stored cross-site scripting in Infoblox NIOS Global Smart Folders allows a user with high privileges on the web interfac
NVD
CVE.org
EPSS
VulDB
GitHub PoC
Exploit-DB