Watchguard
CVE-2022-25360
HIGH
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
WatchGuard Firebox and XTM appliances allow an authenticated remote attacker with unprivileged credentials to upload files to arbitrary locations. This vulnerability impacts Fireware OS before 12.7.2_U2, 12.x before 12.1.3_U8, and 12.2.x through 12.5.x before 12.5.9_U2.
AnalysisAI
WatchGuard Firebox and XTM appliances allow an authenticated remote attacker with unprivileged credentials to upload files to arbitrary locations. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Unrestricted File Upload (CWE-434), which allows attackers to upload malicious files that can be executed on the server. WatchGuard Firebox and XTM appliances allow an authenticated remote attacker with unprivileged credentials to upload files to arbitrary locations. This vulnerability impacts Fireware OS before 12.7.2_U2, 12.x before 12.1.3_U8, and 12.2.x through 12.5.x before 12.5.9_U2. Affected products include: Watchguard Fireware. Version information: before 12.7.2.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate file types server-side, store uploads outside webroot, use random filenames, scan for malware.
More in Watchguard
View allWatchguard XCS 9.2 and 10.0 before build 150522 allow remote authenticated users to execute arbitrary commands via shell
SQL injection vulnerability in Watchguard XCS 9.2 and 10.0 before build 150522 allows remote attackers to execute arbitr
On WatchGuard Firebox and XTM appliances, an unauthenticated user can execute arbitrary code, aka FBX-22786. Rated criti
An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15. Rated critical seve
An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15, and AP300 devices w
WatchGuard RapidStream appliances allow local users to gain privileges and execute arbitrary commands via a crafted ifco
An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15. Rated high severity
An FBX-5312 issue was discovered in WatchGuard Fireware before 12.0. Rated high severity (CVSS 7.5), this vulnerability
WatchGuard Fireware v11.12.1 and earlier mishandles requests referring to an XML External Entity (XXE), in the XML-RPC a
WatchGuard Firebox and XTM appliances allow an unauthenticated remote attacker to retrieve sensitive authentication serv
The AD Helper component in WatchGuard Fireware before 5.8.5.10317 allows remote attackers to discover cleartext password
An FBX-5313 issue was discovered in WatchGuard Fireware before 12.0. Rated medium severity (CVSS 6.1), this vulnerabilit
Same technique File Upload
View allShare
External POC / Exploit Code