Sinumerik Mc Firmware
CVE-2022-24408
HIGH
Severity by source
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
A vulnerability has been identified in SINUMERIK MC (All versions < V1.15 SP1), SINUMERIK ONE (All versions < V6.15 SP1). The sc SUID binary on affected devices provides several commands that are used to execute system commands or modify system files. A specific set of operations using sc could allow local attackers to escalate their privileges to root.
AnalysisAI
A vulnerability has been identified in SINUMERIK MC (All versions < V1.15 SP1), SINUMERIK ONE (All versions < V6.15 SP1). Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Improper Privilege Management (CWE-269), which allows attackers to escalate privileges to gain unauthorized elevated access. A vulnerability has been identified in SINUMERIK MC (All versions < V1.15 SP1), SINUMERIK ONE (All versions < V6.15 SP1). The sc SUID binary on affected devices provides several commands that are used to execute system commands or modify system files. A specific set of operations using sc could allow local attackers to escalate their privileges to root. Affected products include: Siemens Sinumerik Mc Firmware, Siemens Sinumerik One Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply principle of least privilege, validate privilege transitions, implement proper role separation.