Tasy Electronic Medical Record
CVE-2021-39376
HIGH
Severity by source
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter.
AnalysisAI
Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified as SQL Injection (CWE-89), which allows attackers to execute arbitrary SQL commands against the database. Philips Healthcare Tasy Electronic Medical Record (EMR) 3.06 allows SQL injection via the CorCad_F2/executaConsultaEspecifico IE_CORPO_ASSIST or CD_USUARIO_CONVENIO parameter. Affected products include: Philips Tasy Electronic Medical Record.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized queries/prepared statements. Never concatenate user input into SQL. Apply least-privilege database permissions.
Same weakness CWE-89 – SQL Injection
View allShare
External POC / Exploit Code
Leaving vuln.today