Webaccess Scada
CVE-2021-27436
MEDIUM
Severity by source
AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Lifecycle Timeline
1DescriptionNVD
WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions.
AnalysisAI
WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. WebAccess/SCADA Versions 9.0 and prior is vulnerable to cross-site scripting, which may allow an attacker to send malicious JavaScript code to an unsuspecting user, which could result in hijacking of the user’s cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser actions. Affected products include: Advantech Webaccess\/Scada.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.
More in Webaccess Scada
View allAll versions prior to 9.1.4 of Advantech WebAccess/SCADA are vulnerable to use of untrusted pointers. Rated critical sev
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file upload vulnerability that could allow an attack
In Advantech WebAccss/SCADA v9.1.3 and prior, there is an arbitrary file overwrite vulnerability, which could allow an a
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arb
WebAccess/SCADA, Version 8.3. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authent
WebAccess/SCADA, Version 8.3. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authent
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versio
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versio
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versio
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versio
In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versio
Incorrect permissions are set to default on the ‘Project Management’ page of WebAccess/SCADA portal of WebAccess/SCADA V
Same weakness CWE-79 – Cross-site Scripting (XSS)