Idrac9 Firmware
CVE-2021-21542
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Output encoding, context-aware escaping
MITRE ATT&CK
2 techniques across 2 tactics: Initial Access, Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 4.8 (MEDIUM). Attack characteristics: network attack vector, low complexity, high privileges required, user interaction required. |
| Exploit ScenarioDerived | A remote attacker could inject malicious scripts into web pages viewed by other users by sending crafted requests to the affected application. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Dell EMC iDRAC9 versions prior to 4.40.10.00 contain multiple stored cross-site scripting vulnerabilities. Rated medium severity (CVSS 4.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. Dell EMC iDRAC9 versions prior to 4.40.10.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected while generating a certificate. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application. Affected products include: Dell Idrac9 Firmware. Version information: prior to 4.40.10.00.
Know when Idrac9 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Dell EMC iDRAC9 versions prior to 4.40.10.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected while generating a certificate. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Cross-Site Scripting occurs when an application accepts untrusted data and sends it to a web browser without proper validation or encoding.
Affected Products (CPE)NVD
More in Idrac9 Firmware
View allDell EMC iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.10.00, contain an improper authentication vulnerability
Dell EMC iDRAC7, iDRAC8 and iDRAC9 versions prior to 2.65.65.65, 2.70.70.70, 4.00.00.00 contain a stack-based buffer ove
Dell EMC iDRAC9 versions prior to 3.30.30.30 contain an authentication bypass vulnerability. Rated critical severity (CV
Dell EMC iDRAC9 versions prior to 3.24.24.24, 3.21.26.22, 3.22.22.22 and 3.21.25.22 contain an authentication bypass vul
Dell EMC iDRAC6 versions prior to 2.92, iDRAC7/iDRAC8 versions prior to 2.61.60.60, and iDRAC9 versions prior to 3.20.21
Dell EMC iDRAC7/iDRAC8 versions prior to 2.61.60.60 and iDRAC9 versions prior to 3.20.21.20, 3.21.24.22, 3.21.26.22, and
Dell EMC iDRAC7/iDRAC8, versions prior to 2.60.60.60, and iDRAC9 versions prior to 3.21.21.21 contain a command injectio
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a stack-based overflow vulnerability. Rated high severity (CVSS 8.1
Dell EMC iDRAC6, versions prior to 2.91, iDRAC7/iDRAC8, versions prior to 2.60.60.60 and iDRAC9, versions prior to 3.21.
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a Time-of-check Time-of-use (TOCTOU) race condition vulnerability.
Dell EMC iDRAC9 versions prior to 4.20.20.20 contain a Path Traversal Vulnerability. Rated medium severity (CVSS 6.5), t
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a DOM-based cross-site scripting vulnerability. Rated medium severi
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB