Skip to main content

Climatix Pol908 Firmware CVE-2020-7574

MEDIUM
Cross-site Scripting (XSS) (CWE-79)
2020-04-14 productcert@siemens.com
6.1
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
6.1 MEDIUM
AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
Low
Availability
None

Lifecycle Timeline

1
CVE Published
Apr 14, 2020 - 20:15 nvd
MEDIUM 6.1

DescriptionNVD

A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions < V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the "Server Config" web interface of the affected devices that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users' web session.

AnalysisAI

A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions < V11.32). Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions < V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the "Server Config" web interface of the affected devices that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users' web session. Affected products include: Siemens Climatix Pol908 Firmware, Siemens Climatix Pol909 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.

Share

CVE-2020-7574 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy