Rslinx
CVE-2020-12034
HIGH
Severity by source
AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
Lifecycle Timeline
1DescriptionNVD
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.
AnalysisAI
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior,. Rated high severity (CVSS 8.2), this vulnerability is no authentication required, low attack complexity. This SQL Injection vulnerability could allow attackers to execute arbitrary SQL commands against the database.
Technical ContextAI
This vulnerability is classified as SQL Injection (CWE-89), which allows attackers to execute arbitrary SQL commands against the database. Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions. Affected products include: Rockwellautomation Eds Subsystem, Rockwellautomation Rslinx, Rockwellautomation Rslinx Enterprise, Rockwellautomation Rsnetworx, Rockwellautomation Studio 5000 Logix Designer. Version information: Version 28.0.1.
RemediationAI
A vendor patch is available. Apply the latest security update as soon as possible. Use parameterized queries/prepared statements. Never concatenate user input into SQL. Apply least-privilege database permissions.
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. Rated critical severity (CVSS 9.8), this vulnerability is
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. Rated high severity (CVSS 7.5), this vulnerability is rem
A vulnerability was found in Rockwell Automation RSLinx Classic versions 4.10.00 and prior. Rated critical severity (CVS
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. Rated high severity (CVSS 7.5), this vulnerability is rem
Stack-based buffer overflow in OPCTest.exe in Rockwell Automation RSLinx Classic before 3.73.00 allows remote attackers
Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterpris
Same weakness CWE-89 – SQL Injection
View allShare
External POC / Exploit Code
Leaving vuln.today