Mc Works CVE-2020-12009

HIGH
Deserialization of Untrusted Data (CWE-502)
2020-07-16 ics-cert@hq.dhs.gov
7.5
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

1
CVE Published
Jul 16, 2020 - 20:15 nvd
HIGH 7.5

DescriptionNVD

A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.

AnalysisAI

A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Deserialization of Untrusted Data (CWE-502), which allows attackers to execute arbitrary code through malicious serialized objects. A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior. Affected products include: Mitsubishielectric Mc Works, Mitsubishielectric Mc Works32, Iconics Energy Analytix, Iconics Facility Analytix, Iconics Genesis64. Version information: Version 4.02.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid deserializing untrusted data. Use safe serialization formats (JSON). Implement integrity checks and type allowlists.