Skip to main content

Integrated Lights Out 5 Firmware CVE-2019-11982

HIGH
Cross-site Scripting (XSS) (CWE-79)
2019-06-05 security-alert@hpe.com
8.3
CVSS 3.0 · NVD
Share

Severity by source

NVD PRIMARY
8.3 HIGH
AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
High
Privileges Required
None
User Interaction
Required
Scope
Changed
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Jun 05, 2019 - 17:29 nvd
HIGH 8.3

DescriptionNVD

A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.

AnalysisAI

A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier. Rated high severity (CVSS 8.3), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39. Affected products include: Hp Integrated Lights-Out 5 Firmware, Hp Integrated Lights-Out 4 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.

CVE-2023-50272 CRITICAL
9.8 Dec 19

A potential security vulnerability has been identified in HPE Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out

CVE-2022-28640 HIGH
8.8 Sep 20

A potential local adjacent arbitrary code execution vulnerability that could potentially lead to a loss of confidentiali

CVE-2022-28639 HIGH
8.8 Sep 20

A remote potential adjacent denial of service (DoS) and potential adjacent arbitrary code execution vulnerability that c

CVE-2022-28632 HIGH
8.8 Aug 12

A potential arbitrary code execution and a denial of service (DoS) vulnerability within an isolated process were discove

CVE-2022-28631 HIGH
8.8 Aug 12

A potential arbitrary code execution and a denial of service (DoS) vulnerability within an isolated process were discove

CVE-2018-7093 HIGH
8.6 Aug 14

A security vulnerability in HPE Integrated Lights-Out 3 prior to v1.90, iLO 4 prior to v2.60, iLO 5 prior to v1.30, Moon

CVE-2022-28628 HIGH
8.4 Aug 12

A local arbitrary code execution vulnerability was discovered in HPE Integrated Lights-Out 5 (iLO 5) firmware version(s)

CVE-2022-28627 HIGH
8.4 Aug 12

A local arbitrary code execution vulnerability was discovered in HPE Integrated Lights-Out 5 (iLO 5) firmware version(s)

CVE-2022-28638 HIGH
7.8 Sep 20

An isolated local disclosure of information and potential isolated local arbitrary code execution vulnerability that cou

CVE-2022-28637 HIGH
7.8 Sep 20

A local Denial of Service (DoS) and local arbitrary code execution vulnerability that could potentially lead to a loss o

CVE-2022-28629 HIGH
7.8 Aug 12

A local arbitrary code execution vulnerability was discovered in HPE Integrated Lights-Out 5 (iLO 5) firmware version(s)

CVE-2023-30911 HIGH
7.5 Oct 18

HPE Integrated Lights-Out 5, and Integrated Lights-Out 6 using iLOrest may cause denial of service. Rated high severity

Share

CVE-2019-11982 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy