Skip to main content

Tenda CVE-2018-25318

| EUVDEUVD-2018-21839 CRITICAL
Authentication Bypass by Spoofing (CWE-290)
2026-04-29 VulnCheck
9.3
CVSS 4.0 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Anti-spoofing controls
MITRE ATT&CK

1 technique across 1 tactic: Defense Evasion

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 9.3 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available. EPSS exploitation probability: 0.04%.

Exploit ScenarioDerived

This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the critical-severity affected system.

Act Now Prioritize within 24-48h. Why: CRITICAL severity + public POC available.
No patch listed yet 0.0% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Tenda FH303/A300 firmware V5.07.68_EN contains a session weakness vulnerability that allows unauthenticated attackers to modify DNS settings by exploiting insufficient cookie validation. Rated critical severity (CVSS 9.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affected VersionsENISA

FH303/A300 5.07.68

Affected Packages

euvd fh303_a300 no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-290. Tenda FH303/A300 firmware V5.07.68_EN contains a session weakness vulnerability that allows unauthenticated attackers to modify DNS settings by exploiting insufficient cookie validation. Attackers can send GET requests to the /goform/AdvSetDns endpoint with a crafted admin cookie to change DNS servers and redirect user traffic to malicious sites. Affected products include: Tenda Fh303/A300.

Severity by source

NVD PRIMARY 9.3 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
None
Subsequent system: Integrity
None
Subsequent system: Availability
None

Lifecycle Timeline

3
PoC Detected
May 04, 2026 - 18:40 vuln.today
Public exploit code
CVSS changed
Apr 29, 2026 - 20:22 NVD
9.8 (CRITICAL) 9.3 (CRITICAL)
CVE Published
Apr 29, 2026 - 19:24 nvd
CRITICAL 9.3

DescriptionCVE.org

Tenda FH303/A300 firmware V5.07.68_EN contains a session weakness vulnerability that allows unauthenticated attackers to modify DNS settings by exploiting insufficient cookie validation. Attackers can send GET requests to the /goform/AdvSetDns endpoint with a crafted admin cookie to change DNS servers and redirect user traffic to malicious sites.

Threat Intelligence Overview

EPSS Score
0.0%
Top 87% exploitable
Exploit
POC
Public exploit code exists
Data Quality
6 sources
Confidence: High
EUVD NVD CVE.org EPSS Vulnrichment Exploit-DB

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC Yes
EPSS 0.0%
Patch available No
Active threat No
Deciding rule
CRITICAL severity + public POC available
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation
Poc
System Exposure· derived
Open
Automatable
Yes
Human Impact· derived
Medium
Technical Impact
Total

Priority Score

66
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +46
PoC: +20
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.

More in Tenda

View all
CVE-2022-30023 HIGH POC
8.8 Jun 16

Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. Rated high sev

CVE-2015-5995 CRITICAL POC
9.8 Dec 31

Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attacke

CVE-2014-5246 CRITICAL POC
10.0 Aug 22

The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication

CVE-2025-45042 CRITICAL POC
9.8 May 05

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic

CVE-2025-29384 CRITICAL POC
9.8 Mar 14

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability

CVE-2025-44877 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via

CVE-2025-44872 CRITICAL POC
9.8 May 02

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via

CVE-2022-32386 CRITICAL POC
9.8 Jul 06

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CV

CVE-2025-25632 CRITICAL POC
9.8 Mar 05

Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se

CVE-2023-51972 CRITICAL POC
9.8 Jan 10

Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp. Rate

CVE-2023-51812 CRITICAL POC
9.8 Jan 04

Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /

CVE-2023-23080 CRITICAL POC
9.8 Feb 27

Certain Tenda products are vulnerable to command injection. Rated critical severity (CVSS 9.8), this vulnerability is re

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy