Skip to main content

Severity by source

NVD PRIMARY
6.1 MEDIUM
AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
Low
Availability
None

Lifecycle Timeline

1
CVE Published
Oct 12, 2018 - 22:15 nvd
MEDIUM 6.1

DescriptionNVD

WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field.

AnalysisAI

WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field. Rated medium severity (CVSS 6.1), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Cross-Site Scripting (XSS) (CWE-79), which allows attackers to inject malicious scripts into web pages viewed by other users. WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field. Affected products include: Wago 750-362 Firmware, Wago 750-363 Firmware, Wago 750-823 Firmware, Wago 750-832 Firmware, Wago 750-862 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Sanitize all user input, use Content-Security-Policy headers, encode output contextually (HTML, JS, URL). Use frameworks with built-in XSS protection.

CVE-2015-6472 CRITICAL POC
9.8 Aug 22

WAGO IO 750-849 01.01.27 and 01.02.05, WAGO IO 750-881, and WAGO IO 758-870 have weak credential management. Rated criti

CVE-2021-34584 CRITICAL POC
9.1 Oct 26

Crafted web server requests can be utilised to read partial stack or heap memory or may trigger a denial-of- service con

CVE-2021-34586 HIGH POC
7.5 Oct 26

In the CODESYS V2 web server prior to V1.1.9.22 crafted web server requests may cause a Null pointer dereference in the

CVE-2021-34585 HIGH POC
7.5 Oct 26

In the CODESYS V2 web server prior to V1.1.9.22 crafted web server requests can trigger a parser error. Rated high sever

CVE-2021-34583 HIGH POC
7.5 Oct 26

Crafted web server requests may cause a heap-based buffer overflow and could therefore trigger a denial-of- service cond

CVE-2021-30193 CRITICAL
9.8 May 25

CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Write. Rated critical severity (CVSS 9.8), this vulnerability

CVE-2021-30192 CRITICAL
9.8 May 25

CODESYS V2 Web-Server before 1.1.9.20 has an Improperly Implemented Security Check. Rated critical severity (CVSS 9.8),

CVE-2021-30190 CRITICAL
9.8 May 25

CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control. Rated critical severity (CVSS 9.8), this vulnerabilit

CVE-2021-30189 CRITICAL
9.8 May 25

CODESYS V2 Web-Server before 1.1.9.20 has a Stack-based Buffer Overflow. Rated critical severity (CVSS 9.8), this vulner

CVE-2021-30188 CRITICAL
9.8 May 25

CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow. Rated critical severity (CVSS 9.8), this

CVE-2019-10712 CRITICAL
9.8 May 07

The Web-GUI on WAGO Series 750-88x (750-330, 750-352, 750-829, 750-831, 750-852, 750-880, 750-881, 750-882, 750-884, 750

CVE-2021-30194 CRITICAL
9.1 May 25

CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Read. Rated critical severity (CVSS 9.1), this vulnerability

Share

CVE-2018-16210 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy