Edgeswitch Firmware
CVE-2018-12591
HIGH
Severity by source
AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionNVD
Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an improperly neutralized element in an OS command due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary shell instructions.
AnalysisAI
Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an improperly neutralized element in an OS command due to lack of protection on the admin CLI, leading to code execution and privilege. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as OS Command Injection (CWE-78), which allows attackers to execute arbitrary operating system commands on the host. Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an improperly neutralized element in an OS command due to lack of protection on the admin CLI, leading to code execution and privilege escalation greater than administrators themselves are allowed. An attacker with access to an admin account could escape the restricted CLI and execute arbitrary shell instructions. Affected products include: Ubnt Edgeswitch Firmware. Version information: version 1.7.3.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Avoid passing user input to shell commands. Use language-specific APIs instead of shell execution. Apply strict input validation with allowlists.
More in Edgeswitch Firmware
View allA command injection vulnerability exists in EdgeSwitch firmware <v1.9.0 that allowed an authenticated read-only user to
Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root. Rated high sever
Ubiquiti Networks EdgeSwitch version 1.7.3 and prior suffer from an externally controlled format-string vulnerability du
An information disclosure vulnerability exists in EdgeMax EdgeSwitch firmware v1.9.0 that allowed read only users could
DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands. R
Same weakness CWE-78 – OS Command Injection
View allSame technique Privilege Escalation
View allShare
External POC / Exploit Code