Camera Firmware
CVE-2017-6342
CRITICAL
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
1DescriptionCVE.org
An issue was discovered on Dahua DHI-HCVR7216A-S3 devices with NVR Firmware 3.210.0001.10 2016-06-06, Camera Firmware 2.400.0000.28.R 2016-03-29, and SmartPSS Software 1.16.1 2017-01-19. When SmartPSS Software is launched, while on the login screen, the software in the background automatically logs in as admin. This allows sniffing sensitive information identified in CVE-2017-6341 without prior knowledge of the password. This is a different vulnerability than CVE-2013-6117.
AnalysisAI
An issue was discovered on Dahua DHI-HCVR7216A-S3 devices with NVR Firmware 3.210.0001.10 2016-06-06, Camera Firmware 2.400.0000.28.R 2016-03-29, and SmartPSS Software 1.16.1 2017-01-19. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Improper Privilege Management (CWE-269), which allows attackers to escalate privileges to gain unauthorized elevated access. An issue was discovered on Dahua DHI-HCVR7216A-S3 devices with NVR Firmware 3.210.0001.10 2016-06-06, Camera Firmware 2.400.0000.28.R 2016-03-29, and SmartPSS Software 1.16.1 2017-01-19. When SmartPSS Software is launched, while on the login screen, the software in the background automatically logs in as admin. This allows sniffing sensitive information identified in CVE-2017-6341 without prior knowledge of the password. This is a different vulnerability than CVE-2013-6117. Affected products include: Dahuasecurity Camera Firmware, Dahuasecurity Nvr Firmware, Dahuasecurity Smartpss Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply principle of least privilege, validate privilege transitions, implement proper role separation.
More in Camera Firmware
View allACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC fail to properly restrict ac
ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC use non-random default crede
ACTi cameras including the D, B, I, and E series using firmware version A1D-500-V6.11.31-AC have a web application that
An issue in vivotek Network Camera v.FD8166A-VVTK-0204j allows a remote attacker to execute arbitrary code via a crafted
The web interface on Dahua DHI-HCVR7216A-S3 devices with NVR Firmware 3.210.0001.10 2016-06-06, Camera Firmware 2.400.00
Dahua DHI-HCVR7216A-S3 devices with NVR Firmware 3.210.0001.10 2016-06-06, Camera Firmware 2.400.0000.28.R 2016-03-29, a
Same weakness CWE-269 – Improper Privilege Management
View allSame technique Privilege Escalation
View allShare
External POC / Exploit Code
Leaving vuln.today