Skip to main content

Emc Data Domain Os CVE-2017-4983

MEDIUM
2017-05-04 security_alert@emc.com
6.7
CVSS 3.0 · NVD
Share

Severity by source

NVD PRIMARY
6.7 MEDIUM
AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Local
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
May 04, 2017 - 14:29 cve.org
MEDIUM 6.7

DescriptionCVE.org

EMC Data Domain OS 5.2 through 5.7 before 5.7.3.0 and 6.0 before 6.0.1.0 is affected by a privilege escalation vulnerability that may potentially be exploited by attackers to compromise the affected system.

AnalysisAI

EMC Data Domain OS 5.2 through 5.7 before 5.7.3.0 and 6.0 before 6.0.1.0 is affected by a privilege escalation vulnerability that may potentially be exploited by attackers to compromise the affected. Rated medium severity (CVSS 6.7), this vulnerability is low attack complexity. No vendor patch available.

Technical ContextAI

EMC Data Domain OS 5.2 through 5.7 before 5.7.3.0 and 6.0 before 6.0.1.0 is affected by a privilege escalation vulnerability that may potentially be exploited by attackers to compromise the affected system. Affected products include: Dell Emc Data Domain Os. Version information: through 5.7.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2016-0912 CRITICAL
9.8 Jun 19

EMC Data Domain OS 5.4 through 5.7 before 5.7.2.0 allows remote authenticated users to bypass intended password-change r

CVE-2023-23692 HIGH
8.8 Feb 01

Dell EMC prior to version DDOS 7.9 contain(s) an OS command injection Vulnerability. Rated high severity (CVSS 8.8), thi

CVE-2016-0911 HIGH
8.2 Jun 19

EMC Data Domain OS 5.4 through 5.7 before 5.7.2.0 has a default no_root_squash option for NFS exports, which makes it ea

CVE-2023-44285 HIGH
7.8 Dec 14

Dell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an improper access con

CVE-2023-44277 HIGH
7.8 Dec 14

Dell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injectio

CVE-2023-48667 HIGH
7.2 Dec 14

Dell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injectio

CVE-2016-8216 MEDIUM
6.7 Feb 03

EMC Data Domain OS (DD OS) 5.4 all versions, EMC Data Domain OS (DD OS) 5.5 family all versions prior to 5.5.5.0, EMC Da

CVE-2023-44279 MEDIUM
6.7 Dec 14

Dell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injecti

CVE-2023-44278 MEDIUM
6.7 Dec 14

Dell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a path traversal vuln

CVE-2023-44286 MEDIUM
6.1 Dec 14

Dell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain a DOM-based Cross-Sit

CVE-2023-44284 MEDIUM
4.3 Dec 14

Dell PowerProtect DD , versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an SQL Injection vuln

Share

CVE-2017-4983 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy