Skip to main content

Nshield Connect Firmware CVE-2015-1878

MEDIUM
Permissions, Privileges, and Access Controls (CWE-264)
2017-08-18 cve@mitre.org
6.8
CVSS 3.0 · NVD
Share

Severity by source

NVD PRIMARY
6.8 MEDIUM
AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Physical
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Aug 18, 2017 - 16:29 cve.org
MEDIUM 6.8

DescriptionCVE.org

Thales nShield Connect hardware models 500, 1500, 6000, 500+, 1500+, and 6000+ before 11.72 allows physically proximate attackers to sign arbitrary data with previously loaded signing keys, extract the device identification key [KNETI] and impersonate the nShield Connect device on a network, affect the integrity and confidentiality of newly created keys, and potentially cause other unspecified impacts using previously loaded keys by connecting to the USB port on the front panel.

AnalysisAI

Thales nShield Connect hardware models 500, 1500, 6000, 500+, 1500+, and 6000+ before 11.72 allows physically proximate attackers to sign arbitrary data with previously loaded signing keys, extract. Rated medium severity (CVSS 6.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-264. Thales nShield Connect hardware models 500, 1500, 6000, 500+, 1500+, and 6000+ before 11.72 allows physically proximate attackers to sign arbitrary data with previously loaded signing keys, extract the device identification key [KNETI] and impersonate the nShield Connect device on a network, affect the integrity and confidentiality of newly created keys, and potentially cause other unspecified impacts using previously loaded keys by connecting to the USB port on the front panel. Affected products include: Thalesesecurity Nshield Connect Firmware. Version information: before 11.72.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Share

CVE-2015-1878 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy