Rockwell CVE-2012-6435

HIGH
Improper Access Control (CWE-284)
2013-01-24 ics-cert@hq.dhs.gov
7.5
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

2
CVSS changed
Jun 03, 2026 - 14:22 NVD
7.8 (HIGH) 7.5 (HIGH)
CVE Published
Jan 24, 2013 - 21:55 cve.org
HIGH 7.5

DescriptionCVE.org

When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the CPU to stop logic execution and enter a fault state, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices.

Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400

AnalysisAI

When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the CPU to stop logic. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-284. When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the CPU to stop logic execution and enter a fault state, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400 Affected products include: Rockwellautomation Controllogix Controllers, Rockwellautomation Guardlogix Controllers, Rockwellautomation Micrologix, Rockwellautomation Softlogix Controllers, Rockwellautomation 1756-Enbt.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2020-12028 HIGH POC
8.1 Jul 20

In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to int

CVE-2020-12029 HIGH POC
7.8 Jul 20

All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. Rated high s

CVE-2023-2917 CRITICAL POC
9.8 Aug 17

The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability. Rated critical

CVE-2023-27855 CRITICAL POC
9.8 Mar 22

In affected versions, a path traversal exists when processing a message in Rockwell Automation's ThinManager ThinServer.

CVE-2018-14829 CRITICAL POC
9.8 Sep 20

Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. Rated critical severity (CVSS 9.8), this vulnerability is

CVE-2017-7924 HIGH POC
7.5 Sep 20

An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L

CVE-2016-5645 HIGH
7.3 Aug 24

Rockwell Automation MicroLogix 1400 PLC 1766-L32BWA, 1766-L32AWA, 1766-L32BXB, 1766-L32BWAA, 1766-L32AWAA, and 1766-L32B

CVE-2023-2915 CRITICAL POC
9.1 Aug 17

The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, Due to imprope

CVE-2012-6437 CRITICAL
9.8 Jan 24

The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware imag

CVE-2018-19616 HIGH POC
8.1 Dec 26

An issue was discovered in Rockwell Automation Allen-Bradley PowerMonitor 1000. Rated high severity (CVSS 8.1), this vul

CVE-2023-27856 HIGH POC
7.5 Mar 22

In affected versions, path traversal exists when processing a message of type 8 in Rockwell Automation's ThinManager Thi

CVE-2020-6085 HIGH POC
7.5 Oct 19

An exploitable denial of service vulnerability exists in the ENIP Request Path Logical Segment functionality of Allen-Br